Wall coverings and indoor air quality: what criteria should you use to make the right choice?
Indoor air quality is a key consideration in building design and renovation. In both residential and commercial spaces, the materials used contribute to the environment in which occupants live and work daily.
Among them, wall coverings deserve particular attention. Present on sometimes large surfaces, they can contribute to the emission of certain substances into indoor air.
Choosing a suitable wall covering and ensuring good indoor air quality is therefore not solely an aesthetic decision. It also requires examining the material's composition, its emissions, and its installation conditions.
A pleasant interior is not defined solely by what one sees, but also by the quality of the environment in which one lives.

Wall coverings and indoor air quality: understanding the issues
Indoor air quality depends on many parameters: ventilation, occupant activities, cleaning products, furniture, humidity, and construction or decoration materials.
Wall coverings are therefore only one part of this whole, but their choice can help to limit certain sources of pollution.
Depending on their composition and conditions of use, paints, glues, coatings and other finishes can emit volatile substances into the air.
These emissions can be particularly significant during application and during the initial drying phases, and then evolve over time.
For architects and specifiers, it is therefore relevant to consider wall coverings from the material selection phase, rather than addressing the issue of indoor air only at the end of the construction project.
Understanding the role of volatile organic compounds
Volatile organic compounds, commonly known as VOCs, include various chemical substances that can be found in indoor air.
They can come from many sources: materials, decorative products, furniture, household products or certain daily activities.
Not all VOCs have the same properties or the same potential health effects. Their nature, concentration, and duration of exposure must be taken into consideration.
In the field of wall coverings, it is important to distinguish the VOC content of a product before application and the emissions measured after its implementation.
These two pieces of information do not describe exactly the same reality.
A product may, in particular, have a particular formulation while requiring specific tests to characterize its emissions into indoor air.
This is why measured data and technical documents are essential for comparing available solutions.
A+ labeling: a useful indicator for interior finishes
In France, construction and decoration products covered by regulations must display a label indicating their level of emission of volatile pollutants into indoor air.
This classification has four levels, from A+ to C.
Class A+ corresponds to the category with the lowest emissions according to the regulatory criteria adopted.
This labeling provides a first tool for professionals who wish to compare materials.
However, it is important to fully understand its scope.
An A+ rating does not mean that a product has no emissions. Nor does it constitute an overall guarantee of air quality in the building.
Air quality always depends on all the sources present, the conditions of use of the premises and the renewal of the air.
For a relevant prescription, the label must therefore be examined along with other technical information about the product.
Bio-based materials: distinguishing between natural origin and health performance
Interest in bio-based materials is part of a broader reflection on resource use and the environmental impact of buildings.
However, the biological origin of a component is not sufficient to determine the health behavior of a finished product.
A bio-based coating may contain different constituents necessary for its formulation and performance in use.
The nature of the raw materials, any additives, and the manufacturing conditions must be taken into account.
It would therefore be inaccurate to assume that a bio-based material is automatically emission-free or better for indoor air quality.
The most rigorous approach is to examine the test results and classifications corresponding to the marketed product.
This distinction is important for professionals who wish to combine an environmental approach with specific health requirements.
Low emissions and pollutant capture: two different properties
When considering indoor air quality, two concepts are sometimes confused: the limitation of emissions and the potential ability of a material to reduce the concentration of certain pollutants.
A low-emission coating is designed or characterized to release limited amounts of volatile substances under defined test conditions.
Conversely, a material presented as capable of capturing or degrading certain pollutants must be subject to a specific evaluation of this property.
These performances are not interchangeable.
The ability of a material to act on a given pollutant does not allow us to conclude that it acts on all substances present in the air.
It also does not eliminate the need for adequate ventilation.
For specifiers, it is essential to verify the nature of the pollutants studied, the test methods, the measurement conditions and the results available before retaining such a property in a project.
Application, drying and ventilation: do not neglect the work site
Indoor air quality does not depend solely on the initial choice of products.
Application conditions, drying times and site organization can also influence emissions and exposure of workers.
A coating must be applied in accordance with the manufacturer's recommendations, particularly regarding substrate preparation, ambient conditions and time before occupancy of the premises.
Ventilation during and after work must be adapted to the products used and the applicable regulations.
It is also important to take into account other materials used simultaneously, such as primers, adhesives or protective products.
The evaluation of a wall finish should therefore focus on the system actually used, and not solely on its main component.
This approach is particularly important in buildings open to the public and spaces occupied on a daily basis.
Integrating indoor air quality from the architectural design stage
The selection of materials can be integrated into a more comprehensive approach to space design.
For an architect or project manager, this involves relating aesthetic requirements, technical characteristics and available health data.
In a hotel, office, accommodation or reception area, usage constraints may vary, but the need for reliable information remains the same.
The choice of coatings must also be coordinated with ventilation solutions, maintenance practices and the operating conditions of the building.
A coherent approach does not consist of seeking a material presented as perfect, but of selecting solutions whose properties are known, documented and adapted to their purpose.
ABSOLIN: combining architectural expression and attention to materials
At ABSOLIN , the approach to bio-based decorative coatings is part of a reflection on the place of matter in interior spaces.
Beyond texture and architectural appearance, the choice of a coating invites consideration of its composition, its documented characteristics and the conditions of its implementation.
Indoor air quality is one of the topics that designers can incorporate into this thinking.
For architects, decorators and specifiers, the challenge lies in reconciling aesthetic intentions with the technical and health requirements of the project.
The specific performance of a solution should always be assessed from the documents and test results corresponding to the product concerned.
A choice of material that is part of a comprehensive approach
Indoor air quality never depends on a single material.
It results from the interaction between pollution sources, building characteristics, ventilation and daily uses.
The choice of wall coverings nevertheless represents an important step in limiting certain emissions and better controlling the materials introduced into spaces.
By examining the available data, the conditions of application and the project requirements, professionals can integrate this issue from the design stage.
The choice of wall coverings is part of a comprehensive reflection on materials and the interior environment.
Are you looking for a decorative coating for a design or renovation project?
Discover ABSOLIN solutions and discuss with our team to study the characteristics of the materials and their suitability for your project.
Contact ABSOLIN: 05 46 99 04 51




Comments